Automatic Current Sensing Switch For Dust Collector

Automatic Current Sensing Switch For Dust Collector

I have installed an automatic dust extraction system in my shed with automatic blast gates, etc and one of the things I needed was a way to sense when things like the pedestal drill, SCMS and other plug in 240V items are running. I came across this website which goes into detail about a current sense slave switch -Current Sensing Slave Power Switch

We are a professional mining machinery manufacturer, the main equipment including: jaw crusher, cone crusher and other sandstone equipment;Ball mill, flotation machine, concentrator and other beneficiation equipment; Powder Grinding Plant, rotary dryer, briquette machine, mining, metallurgy and other related equipment.If you are interested in our products or want to visit the nearby production site, you can click the picture on the right to contact us.

New Products

We provide quality and efficient products to our global customers

about us

Focusing on mining machinery for 40 years, We are has provided professional project guidance, equipment production, production line construct, management and operation services for more than one million customers.

  • Reply by email within 24 hours
  • Free maintenance within 12 months
  • 7 * 24 After sales service
Get Price
  • 40+

    Years Of History

  • 600+

    Senior Enginner

  • 160+

    Served Countries

about

COMPANY INFORMATION

If you have any requirements, suggestions and comments on our products, please leave a message! You will be replied as soon as you see the information. Thank you!

pic
  • Rockler Dust Collector Remote Switch

    Rockler Dust Collector Remote Switch

    Turns my dust collector on and off. Used tue 240 v for 10 years or more until the dust collector gave up. Buy it you will be happy with it. Reply Inaccurate FRED M on Jan 3, 2019 Purchased on Jan 11, 2017

    Read More
  • Current Switches at Best Price in India

    Current Switches at Best Price in India

    Current Switch Clamped Ask Price Ideal for HVACR, industrial, and lighting applications that use electric motors to drive fans, pumps, and blowers, and for sensing the status of heating coils and lighting

    Read More
  • Automatic Dust Collector Blast Gate Controller

    Automatic Dust Collector Blast Gate Controller

    My dust collector is an Oneida Smart Pro 5HP unit with an RF remote. In my small one person shop, the dust collector does not run continuously only when machines are producing chips. I wanted the dust collector to turn on automatically whenever I turned on the saw. The blast gate must open at the same time.

    Read More
  • Accessories   Farr Dust Collector FDC Controller by

    Accessories Farr Dust Collector FDC Controller by

    The Farr Dust Collector FDC Controllers flexible design allows it to be adapted to many dust collector configurations. The Timer Control Module will sequentially pulse up to ten outputs in On-Demand mode, based upon the Pressure Switch closure on the Pressure Differential Meter.

    Read More
  • Series CCS  Current Switch is ideal for monitoring the

    Series CCS Current Switch is ideal for monitoring the

    The SERIES CCS Current Switches are ideal for monitoring the operating status of fans, pumps, and motors. These self-powered switches can be hung or tied directly to cables or wires. For use on existing installations, split core models can be installed without disconnecting cables.

    Read More
  • Current Sensing Switches Current Sensing Relays

    Current Sensing Switches Current Sensing Relays

    SENSING APERTURE ATS SERIES - SWITCH SETPOINT Switch Selectable 101200 A Electromechanical SPDT Relay, Plus 4 - 20 mA 120 VAC or 24 VDC 1.875 dia. ATS SERIES - DIGITAL SETPOINT Switch Adjustment 150 A or 4200 A depending on model Isolated Solid-State Relay, 1.0 A Max Plus 420 mA, 05 VDC or 010 VDC 1830 VACDC 0 ...

    Read More
  • Dust collection automation   festoolownersgroupm

    Dust collection automation festoolownersgroupm

    . turn on the dust collector, If it is not already on When turning off equipment 1. Automatically close the blast gate 2. wait 15 seconds and turn off the dust collector if all blast gates are closed To do this I decided to use 1. Arduino Mega 2. LCD color touch screen 3. Current sensing relays 4. 12 volt Relay board with 16 relays

    Read More
  • Dust Collection Accessories at Rockler Hose Reels

    Dust Collection Accessories at Rockler Hose Reels

    From blowers to cord and hose holders, Rockler has a wide variety of dust collection accessories. Shop now to find the perfect one for you. Dust Collection Accessories at Rockler Hose Reels, Dust Bags

    Read More
  • Automated Dust Collection for Woodworking Shop

    Automated Dust Collection for Woodworking Shop

    In my time performing technical support at Functional Devices, Inc., several customers have requested assistance selecting RIB products that would enable them to automate the dust collection system in their woodworking shop. In each scenario, they were looking for a way to have their dust collector turn on if any of their electric saws, sanders or drills were being used.

    Read More
  • I found cheap simple current sense switches for dust

    I found cheap simple current sense switches for dust

    Google current sensing switch and youll find a lot of relatively cheap products. Yes, you can get down to the circuit level and build your own, but for an industrial quality control for 15, plus a relay I have several laying around, Ill go that route.

    Read More
  • 240V iVAC Pro Automated Dust Collector Control

    240V iVAC Pro Automated Dust Collector Control

    Mitigate airborne dust and reduce cleanup with a unique system that automatically turns on your 220-240V dust collector e.g. Dust Cobra, Mini-Gorilla as soon as your powers tools are in use. Includes a wireless RF remote with belt-clip. Compatible with automatic iVAC Pro Tool Plus sensors.

    Read More
  • Load Sensing Automatic Switch   sound aum

    Load Sensing Automatic Switch sound aum

    The primary 110, 220 or 240V will supply a low current signal proportional to the current being drawn by the controlling load. We dont care about the current, just if it is there or not. In my tests, I found that a typical 240V to 12V transformer and a 110V to 7V unit both worked fine with a 1k load across the original primary winding.

    Read More
  • Current activated switch   DIYWiki   DIY FAQ

    Current activated switch DIYWiki DIY FAQ

    The current sensing is done in a non invasive way that does not require modification of the circuit being monitored. ... Note that on very light loads the circuit may take a few moment to switch the relay. For reliably sensing low loads, ... Tool controlled dust collector.

    Read More
  • Automatic dust collection switch   by BOBAH

    Automatic dust collection switch by BOBAH

    At some points in the past, I owned and enjoyed automatic vacuum switch solutions from DGC and IVAC. Unfortunately, both have had reliability issues, so I decided to build my own, more powerful version. Essentially, this is a portable, 110V version of automatic dust collection switch published in August 2000 issue of Fine Woodworking magazine.

    Read More
  • iVac   Automated Shop Vacuum Switch

    iVac Automated Shop Vacuum Switch

    The Intelligent Vacuum Switch eliminates the distraction of turning on and off a dust collection system while you are operating potentially dangerous power tools. Received ETL safety approval. Three modes of operation Auto, Off , On and Turn-On delay avoids the

    Read More
  • Making an Arduino Driven Automated Dust

    Making an Arduino Driven Automated Dust

    The system works great except for one component that kept giving us trouble. The 15 amp relay that was controlling the dust collector would fail after a few days. After some research, I discovered that they were a bit underpowered for the 2 horsepower DC. I have ordered a beefier relay and when we get it hooked up and working, itll be listed ...

    Read More
  • How To Make An Automatic Load Sensing Switch

    How To Make An Automatic Load Sensing Switch

    Making an load sensing switch to turn on my shop vac. This is another project that Ive been meaning to make for a while, and with my change to localized dust collection, I figured now was as good a time as any.. First, a word of warning this project deals with mains voltage, and if you have any doubts or concerns about working with it, this project may not be for you.

    Read More
  • Current sensing relay with delay on break for dust

    Current sensing relay with delay on break for dust

    I have a large 20A Dust Collector that needs to be on its own circuit or else it will trip. I also have a ceiling mounted air cleaner to get any fine particles that get airborne. ... begingroup Matt Not sure if I accurately portrayed how the current sensing switch is wired. It may be self-powered. ... Automatic ranging current sensing. 0.

    Read More
  • Automatic current sensing DC control with barrel

    Automatic current sensing DC control with barrel

    This will allow the dust collector to stay on for 5 seconds when I turn my saw off. I also used the Hawkeye 800 current sensing relay that BrainHood and JohnWho suggested above. I then added a manual switch and a 1ch 433Mhz wireless RF remote control switch to be able to turn the dust collector on and off at will.

    Read More
  • Dust collector auto switch for 240v tool   JLC Online

    Dust collector auto switch for 240v tool JLC Online

    Re Dust collector auto-switch for 240v tool Cant you just switch ONE leg of the 240 volt circuit Or use a two pole switch. Use the same switches and wiring. As long as the switch is rated for the tool and collectors current it should work fine. At 220 volt the current will be less anyway.

    Read More
  • iVAC Pro Dust Collector Remote Switch   iVac

    iVAC Pro Dust Collector Remote Switch iVac

    For example, when a 1.5HP 115Vac Dust Collector is turned on there is an initial surge current of up to 75 Amps. Lesser systems will either trip a circuit breaker, blow a fuse or break down. Whats more, repeated usage tends to wear down the mechanical relay components and can lead to the failure of a less robust product. iVAC products are ...

    Read More
  • How to build a current detector switch circuit for

    How to build a current detector switch circuit for

    I think you can buy these ready-made, but a search was not too productive. I have a friend who wanted one to automate his shop dust collector, but i think he wound up buying a remote controlled switch instead. Some of the ideas I found in the search passed one side of all the loads to be sensed through a toroid, sensing the current.

    Read More
  • AUTOMATIC DUST COLLECTION FOR SMALL SHOPS

    AUTOMATIC DUST COLLECTION FOR SMALL SHOPS

    sensing and collector operation due to a constant current being drawn by the control system. Place the power cord into the groove on the sensor. Next place the clip over the cord such that the hook ends on the clip are toward the notches at both sides of the sensor. Now press

    Read More
  • Automatic dust collection starting with 220 table saw

    Automatic dust collection starting with 220 table saw

    Re Automatic dust collection starting with 220 table saw 05-25-2016, 1130 AM If you are creative with your wiring, get a 220v contractor and feed it from from your TS, then the other part will act as a switch turning the 110v off and on.

    Read More
  • Automated Controls for a Variable Speed Dust

    Automated Controls for a Variable Speed Dust

    Any 24V AC current applied to the coil will close the contacts to the blower motor. You then mount one of the magnetic switches to your dust gate. You want to use a switch that will close the contacts when the gate is opened. This is best done by mounting the switch on

    Read More